← Back
CWE-248

271 CVEs • Abstraction: Base

Uncaught Exception

An exception is thrown from a function, but it is not caught.

JSON object

Loading...

CVEs (271)

CVE
VENDORS
PRODUCTS
UPDATED
PUBLISHED
CVSS
1Schneider Electric
4Modicon M340 Firmware
Modicon M580 FirmwareModicon Premium Firmware+1 more
Jun 17, 2026
Sep 17, 2019
N/A· v4
7.5 HIGH· v3
7.8 HIGH· v2
A CWE-248: Uncaught Exception vulnerability exists Modicon M580 (firmware version prior to V2.90), Modicon M340 (firmware version prior to V3.10), Modicon Premium (all versions), and Modicon Quantum (all versions), which...Show more
A CWE-248: Uncaught Exception vulnerability exists Modicon M580 (firmware version prior to V2.90), Modicon M340 (firmware version prior to V3.10), Modicon Premium (all versions), and Modicon Quantum (all versions), which could cause a possible denial of service when reading specific coils and registers in the controller over Modbus.Show less
1Schneider Electric
4Modicon M340 Firmware
Modicon M580 FirmwareModicon Premium Firmware+1 more
Jun 17, 2026
Sep 17, 2019
N/A· v4
7.5 HIGH· v3
7.8 HIGH· v2
A CWE-248: Uncaught Exception vulnerability exists in Modicon M580 (firmware versions prior to V2.90), Modicon M340 (firmware versions prior to V3.10), Modicon Premium (all versions), Modicon Quantum (all versions), whic...Show more
A CWE-248: Uncaught Exception vulnerability exists in Modicon M580 (firmware versions prior to V2.90), Modicon M340 (firmware versions prior to V3.10), Modicon Premium (all versions), Modicon Quantum (all versions), which could cause a possible denial of service when reading invalid data from the controller.Show less
1Siemens
2Digsi 5 Engineering Software
Siprotec 5 Digsi Device Driver
Jun 17, 2026
Jul 11, 2019
N/A· v4
7.5 HIGH· v3
5.0 MEDIUM· v2
A vulnerability has been identified in All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions ), DIGSI 5 engineering software (All versions < V...Show more
A vulnerability has been identified in All other SIPROTEC 5 device types with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions ), DIGSI 5 engineering software (All versions < V7.90), SIPROTEC 5 device types 6MD85, 6MD86, 6MD89, 7UM85, 7SA87, 7SD87, 7SL87, 7VK87, 7SA82, 7SA86, 7SD82, 7SD86, 7SL82, 7SL86, 7SJ86, 7SK82, 7SK85, 7SJ82, 7SJ85, 7UT82, 7UT85, 7UT86, 7UT87 and 7VE85 with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.90), SIPROTEC 5 device types 7SS85 and 7KE85 (All versions < V8.01), SIPROTEC 5 device types with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.59), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.59). Specially crafted packets sent to port 443/TCP could cause a Denial of Service condition.Show less
1Schneider Electric
4Modicon M340 Firmware
Modicon M580 FirmwareModicon Premium Firmware+1 more
Jun 17, 2026
May 22, 2019
N/A· v4
7.5 HIGH· v3
5.0 MEDIUM· v2
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when an invalid private command parameter is...Show more
A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when an invalid private command parameter is sent to the controller over Modbus.Show less
1Siemens
4Simatic Pcs 7
Simatic WinccSimatic Wincc (tia Portal)+1 more
Jun 17, 2026
May 14, 2019
N/A· v4
5.5 MEDIUM· v3
2.1 LOW· v2
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11...Show more
A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An attacker with local access to the project file could cause a Denial-of-Service condition on the affected product while the project file is loaded. Successful exploitation requires access to the project file. An attacker could use the vulnerability to compromise availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known.Show less
1Siemens
27Opc Unified Architecture
Simatic Cp443 1 Opc Ua FirmwareSimatic Et 200 Open Controller Cpu 1515sp Pc2 Firmware+24 more
Jun 17, 2026
Apr 17, 2019
N/A· v4
7.5 HIGH· v3
7.8 HIGH· v2
A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (i...Show more
A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R family (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions < V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication.Show less
1Sonicwall
2Sonicos
Sonicosv
Jun 17, 2026
Apr 2, 2019
N/A· v4
6.5 MEDIUM· v3
4.0 MEDIUM· v2
A vulnerability in SonicWall SonicOS and SonicOSv, allow authenticated read-only admin to leave the firewall in an unstable state by downloading certificate with specific extension. This vulnerability affected SonicOS Ge...Show more
A vulnerability in SonicWall SonicOS and SonicOSv, allow authenticated read-only admin to leave the firewall in an unstable state by downloading certificate with specific extension. This vulnerability affected SonicOS Gen 5 version 5.9.1.10 and earlier, Gen 6 version 6.2.7.3, 6.5.1.3, 6.5.2.2, 6.5.3.1, 6.2.7.8, 6.4.0.0, 6.5.1.8, 6.0.5.3-86o and SonicOSv 6.5.0.2-8v_RC363 (VMWARE), 6.5.0.2.8v_RC367 (AZURE), SonicOSv 6.5.0.2.8v_RC368 (AWS), SonicOSv 6.5.0.2.8v_RC366 (HYPER_V).Show less
1Siemens
5Sinumerik 808d V4.7 Firmware
Sinumerik 808d V4.8 FirmwareSinumerik 828d V4.7 Firmware+2 more
Nov 21, 2024
Dec 12, 2018
N/A· v4
9.8 CRITICAL· v3
7.5 HIGH· v2
A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINU...Show more
A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). Specially crafted network packets sent to port 102/tcp (ISO-TSAP) could allow a remote attacker to either cause a Denial-of-Service condition of the integrated software firewall or allow to execute code in the context of the software firewall. The security vulnerability could be exploited by an attacker with network access to the affected systems on port 102/tcp. Successful exploitation requires no user privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was knownShow less
1Siemens
5Sinumerik 808d V4.7 Firmware
Sinumerik 808d V4.8 FirmwareSinumerik 828d V4.7 Firmware+2 more
Nov 21, 2024
Dec 12, 2018
N/A· v4
7.8 HIGH· v3
7.2 HIGH· v2
A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINU...Show more
A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). A local attacker could use ioctl calls to do out of bounds reads, arbitrary writes, or execute code in kernel mode. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.Show less
1Siemens
2Sinumerik 828d Firmware
Sinumerik 840d Sl Firmware
Nov 21, 2024
Dec 12, 2018
N/A· v4
3.7 LOW· v3
4.3 MEDIUM· v2
A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated VNC server...Show more
A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to cause a Denial-of-Service condition of the VNC server. Please note that this vulnerability is only exploitable if port 5900/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices and port. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise availability of the VNC server. At the time of advisory publication no public exploitation of this security vulnerability was known.Show less
1Elastic
1Logstash
May 13, 2026
Jun 16, 2017
N/A· v4
7.5 HIGH· v3
5.0 MEDIUM· v2
Logstash versions prior to 2.3.3, when using the Netflow Codec plugin, a remote attacker crafting malicious Netflow v5, Netflow v9 or IPFIX packets could perform a denial of service attack on the Logstash instance. The e...Show more
Logstash versions prior to 2.3.3, when using the Netflow Codec plugin, a remote attacker crafting malicious Netflow v5, Netflow v9 or IPFIX packets could perform a denial of service attack on the Logstash instance. The errors resulting from these crafted inputs are not handled by the codec and can cause the Logstash process to exit.Show less