CVE
VENDORS
PRODUCTS
UPDATED
PUBLISHED
CVSS
1Juniper
1Junos
Jul 13, 2026
Jul 9, 2026
7.1 HIGH· v4
6.5 MEDIUM· v3
N/A· v2
An Improper Handling of Undefined Parameters vulnerability in the packet forwarding engine (pfe) of Juniper Networks Junos OS on EX Series devices allows an authenticated attacker with low privileges to cause a Denial-of...Show more
An Improper Handling of Undefined Parameters vulnerability in the packet forwarding engine (pfe) of Juniper Networks Junos OS on EX Series devices allows an authenticated attacker with low privileges to cause a Denial-of-Service (DoS). If an attempt is made to subscribe to an unsupported telemetry sensor path on EX2300, EX3400, EX4000, EX4100 and EX4400 via gRPC, this causes the FPC to crash. This leads to a complete service outage until the module has automatically restarted.  The following log message can be seen when this issue happens: agentd[<PID>]: AGENTD_RESOURCE_NOT_FOUND: No resource name found for <sensor> This issue affects Junos OS on EX2300, EX3400, EX4000, EX4100 and EX4400 devices: * all versions before 23.2R2-S7, * 23.4 versions before 23.4R2-S8, * 24.2 versions before 24.2R2-S5, * 24.4 versions before 24.4R2.Show less
1Cisco
1Asa Firepower
Jun 17, 2026
Jun 24, 2022
N/A· v4
7.2 HIGH· v3
9.0 HIGH· v2
A vulnerability in the CLI parser of Cisco FirePOWER Software for Adaptive Security Appliance (ASA) FirePOWER module could allow an authenticated, remote attacker to execute arbitrary commands on the underlying operating...Show more
A vulnerability in the CLI parser of Cisco FirePOWER Software for Adaptive Security Appliance (ASA) FirePOWER module could allow an authenticated, remote attacker to execute arbitrary commands on the underlying operating system of an affected ASA FirePOWER module as the root user. This vulnerability is due to improper handling of undefined command parameters. An attacker could exploit this vulnerability by using a crafted command on the CLI or by submitting a crafted HTTPS request to the web-based management interface of the Cisco ASA that is hosting the ASA FirePOWER module. Note: To exploit this vulnerability, the attacker must have administrative access to the Cisco ASA. A user who has administrative access to a particular Cisco ASA is also expected to have administrative access to the ASA FirePOWER module that is hosted by that Cisco ASA.Show less