CVE-2026-63248
6.9
Vector
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:XShow more
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:XShow less
Source: emo@eclipse.org (Secondary)
Description
In Eclipse Milo versions 0.6.0 through 1.1.4, OPC UA server diagnostics nodes do not enforce access authorization. An anonymous client can enable diagnostics over a None/None endpoint without a certificate; with a trusted client application certificate over SignAndEncrypt, it can read security diagnostics for other active sessions, exposing usernames, login history, authentication mechanisms, security modes and policies, and public client certificates.
Affected (1)
References (3)
Source: emo@eclipse.org
Patch
Source: emo@eclipse.org
Issue TrackingPatchVendor Advisory
Source: emo@eclipse.org
Issue TrackingVendor Advisory
Timeline
No history available yet.