CVE-2026-3274
7.4
Vector
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:XShow more
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:XShow less
Source: CNA (Secondary)
Description
A security flaw has been discovered in Tenda F453 1.0.0.3. Affected by this issue is the function frmL7ProtForm of the file /goform/L7Prot of the component httpd. Performing a manipulation of the argument page results in buffer overflow. The attack is possible to be carried out remotely. The exploit has been released to the public and may be used for attacks.
Affected (1)
Products: Tenda: F453 Firmware
Configuration A
| Vulnerable Software | Affected Versions |
|---|---|
| Version 1.0.0.3 |
| Running on/with | Platform Versions |
|---|---|
Tenda F453 | All versions |
Related CWEs
CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
The product performs operations on a memory buffer, but it reads from or writes to a memory location outside the buffer's intended boundary. This may result in read or write operations on unexpected memory locations that could be linked to other variables, data structures, or internal program data.
CWE-120
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
The product copies an input buffer to an output buffer without verifying that the size of the input buffer is less than the size of the output buffer, leading to a buffer overflow.
References (5)
Source: cna@vuldb.com
ExploitThird Party Advisory
Timeline
No history available yet.