CVE-2026-25599
6.3
Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L
Exploitability: 2.8 / Impact: 3.4
Source: a6d3dc9e-0591-4a13-bce7-0f5b31ff6158 (Secondary)
Description
Missing authentication and clear‑text transmission of data from the heat pumps to the control server, combined with the absence of input validation on aggregated data, can lead to stored XSS that enables theft of cookies from the pump’s web control interface. Older Orca heat pump devices communicating with the Orca server over an
unencrypted and unauthenticated HTTP connection on a non-secure port specifically enable an
attacker to impersonate a legitimate device and inject malicious
payloads. This enables the insertion of harmful code directly
into the Orca user portal, potentially compromising user accounts,
exposing sensitive information, and allowing further unauthorized
actions within the portal.
Related CWEs
CWE-306
Missing Authentication for Critical Function
The product does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources.
CWE-319
Cleartext Transmission of Sensitive Information
The product transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors.
CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
The product does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is served to other users.
References (1)
Source: a6d3dc9e-0591-4a13-bce7-0f5b31ff6158
Timeline
No history available yet.