CVE-2026-2250
7.5
Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Exploitability: 3.9 / Impact: 3.6
Source: 56a186b1-7f5e-4314-ba38-38d5499fccfd (Secondary)
Description
The /dbviewer/ web endpoint in METIS WIC devices is exposed without authentication. A remote attacker can access and export the internal telemetry SQLite database containing sensitive operational data. Additionally, the application is configured with debug mode enabled, causing malformed requests to return verbose Django tracebacks that disclose backend source code, local file paths, and system configuration.
Related CWEs
CWE-215
Insertion of Sensitive Information Into Debugging Code
The product inserts sensitive information into debugging code, which could expose this information if the debugging code is not disabled in production.
CWE-284
Improper Access Control
The product does not restrict or incorrectly restricts access to a resource from an unauthorized actor.
References (2)
Source: 56a186b1-7f5e-4314-ba38-38d5499fccfd
Source: 56a186b1-7f5e-4314-ba38-38d5499fccfd
Timeline
No history available yet.