CVE-2025-66052
8.6
Vector
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:XShow more
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:XShow less
Source: cvd@cert.pl (Secondary)
Description
Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter "system_ntpIt" used by "/cgi-bin/admin/setparam.cgi" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access is not protected by default,
The vendor has not replied to the CNA Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
Affected (1)
Products: Vivotek: Ip7137 Firmware
Configuration A
| Vulnerable Software | Affected Versions |
|---|---|
| Version 0200a |
| Running on/with | Platform Versions |
|---|---|
Vivotek Ip7137 | All versions |