Description

Autel MaxiCharger AC Wallbox Commercial Origin Validation Error Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Autel MaxiCharger AC Wallbox Commercial. An attacker must first obtain the ability to pair a malicious Bluetooth device with the target system in order to exploit this vulnerability. The specific flaw exists within the handling of bluetooth pairing requests. The issue results from insufficient validation of the origin of commands. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-26353.

Affected (18)

9 products
Maxicharger Ac Pro Firmware
Maxicharger Ac Ultra Firmware
Maxicharger Dc Fast Firmware
Maxicharger Dc Hipower Firmware
Maxicharger Dh480 Firmware
Configuration A
2 vulnerable · 1 platform
Vulnerable SoftwareAffected Versions
Autel
Before 1.39.51
Before 1.56.51
Running on/withPlatform Versions
Autel
Maxicharger Ac Elite Business C50
All versions
Configuration B
2 vulnerable · 1 platform
Vulnerable SoftwareAffected Versions
Autel
Before 1.39.51
Before 1.56.51
Running on/withPlatform Versions
Autel
Maxicharger Ac Pro
All versions
Configuration C
2 vulnerable · 1 platform
Vulnerable SoftwareAffected Versions
Autel
Before 1.39.51
Before 1.56.51
Running on/withPlatform Versions
Autel
Maxicharger Ac Ultra
All versions
Configuration D
2 vulnerable · 1 platform
Vulnerable SoftwareAffected Versions
Autel
Before 1.39.51
Before 1.56.51
Running on/withPlatform Versions
Autel
Maxicharger Dc Compact Mobile
All versions
Configuration E
2 vulnerable · 1 platform
Vulnerable SoftwareAffected Versions
Autel
Before 1.39.51
Before 1.56.51
Running on/withPlatform Versions
Autel
Maxicharger Dc Compact Pedestal
All versions
Configuration F
2 vulnerable · 1 platform
Vulnerable SoftwareAffected Versions
Autel
Before 1.39.51
Before 1.56.51
Running on/withPlatform Versions
Autel
Maxicharger Dc Fast
All versions
Configuration G
2 vulnerable · 1 platform
Vulnerable SoftwareAffected Versions
Autel
Before 1.39.51
Before 1.56.51
Running on/withPlatform Versions
Autel
Maxicharger Dc Hipower
All versions
Configuration H
2 vulnerable · 1 platform
Vulnerable SoftwareAffected Versions
Autel
Before 1.39.51
Before 1.56.51
Running on/withPlatform Versions
Autel
Maxicharger Dh480
All versions
Configuration I
2 vulnerable · 1 platform
Vulnerable SoftwareAffected Versions
Autel
Before 1.39.51
Before 1.56.51
Running on/withPlatform Versions
Autel
Maxicharger Single Charger
All versions

References (1)

Source: zdi-disclosures@trendmicro.com
Third Party Advisory

Timeline

No history available yet.