Source: productcert@siemens.com (Secondary)
Description
Affected devices do not properly sanitize contents of trace files.
This could allow an attacker to inject code through social engineering an authorized user, who has the function right "Read diagnostics", to import a specially crafted trace file.
The malicious trace file is insufficiently sanitized and malicious code could be executed in the clients browser session and trigger PLC operations via the webserver that the legitimate user is authorized to perform.
Related CWEs
CWE-79
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
The product does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is served to other users.
CWE-95
Improper Neutralization of Directives in Dynamically Evaluated Code ('Eval Injection')
The product receives input from an upstream component, but it does not neutralize or incorrectly neutralizes code syntax before using the input in a dynamic evaluation call (e.g. "eval").