CVE-2025-34217
10.0
Vector
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:XShow more
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:XShow less
Source: disclosure@vulncheck.com (Secondary)
Description
Vasion Print (formerly PrinterLogic) Virtual Appliance Host and Application (VA/SaaS deployments) contain an undocumented 'printerlogic' user with a hardcoded SSH public key in '~/.ssh/authorized_keys' and a sudoers rule granting the printerlogic_ssh group 'NOPASSWD: ALL'. Possession of the matching private key gives an attacker root access to the appliance.
Affected (2)
Configuration A
| Vulnerable Software | Affected Versions |
|---|---|
| All versions | |
| All versions |
References (5)
Source: disclosure@vulncheck.com
Vendor Advisory
Source: disclosure@vulncheck.com
Vendor Advisory
Source: disclosure@vulncheck.com
ExploitThird Party Advisory
Source: disclosure@vulncheck.com
Broken Link
Source: 134c704f-9b21-4f2e-91b3-4a467353bcc0
ExploitThird Party Advisory
Timeline
No history available yet.