← Back

CVE-2025-34208

nvd nist
Published: Oct 2, 2025Modified: Jun 17, 2026

JSON object

Loading...
8.2
Vector
CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Show more
CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:XShow less
Source: disclosure@vulncheck.com (Secondary)

Description

Vasion Print (formerly PrinterLogic) Virtual Appliance Host and Application (VA/SaaS deployments) store user passwords using unsalted SHA-512 hashes with a fall-back to unsalted SHA-1. The hashing is performed via PHP's `hash()` function in multiple files (server_write_requests_users.php, update_database.php, legacy/Login.php, tests/Unit/Api/IdpControllerTest.php). No per-user salt is used and the fast hash algorithms are unsuitable for password storage. An attacker who obtains the password database can recover cleartext passwords via offline dictionary or rainbow table attacks. The vulnerable code also contains logic that migrates legacy SHA-1 hashes to SHA-512 on login, further exposing users still on the old hash. This vulnerability was partially resolved, but still present within the legacy authentication platform.

Affected (2)

2 products
Virtual Appliance Application
Virtual Appliance Host
Configuration A
2 vulnerable
Vulnerable SoftwareAffected Versions
All versions
All versions

Timeline

No history available yet.