CVE-2024-4240
8.8
Vector
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Exploitability: 2.8 / Impact: 5.9
Source: NVD
Description
A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been classified as critical. This affects the function formQosManageDouble_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-262131. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Affected (1)
Products: Tenda: W9 Firmware
Configuration A
| Vulnerable Software | Affected Versions |
|---|---|
| Version 1.0.0.7(4456) |
| Running on/with | Platform Versions |
|---|---|
Tenda W9 | All versions |
Related CWEs
CWE-121
Stack-based Buffer Overflow
A stack-based buffer overflow condition is a condition where the buffer being overwritten is allocated on the stack (i.e., is a local variable or, rarely, a parameter to a function).
CWE-787
Out-of-bounds Write
The product writes data past the end, or before the beginning, of the intended buffer.
References (8)
Source: cna@vuldb.com
Broken Link
Source: cna@vuldb.com
Permissions RequiredThird Party AdvisoryVDB Entry
Source: af854a3a-2127-422b-91ae-364da2661108
Broken Link
Source: af854a3a-2127-422b-91ae-364da2661108
Permissions RequiredThird Party AdvisoryVDB Entry
Source: af854a3a-2127-422b-91ae-364da2661108
Third Party AdvisoryVDB Entry
Source: af854a3a-2127-422b-91ae-364da2661108
Third Party AdvisoryVDB Entry
Timeline