A vulnerability has been identified in Opcenter Execution Foundation (All versions < V2407), Opcenter Quality (All versions < V2312), SIMATIC PCS neo (All versions < V4.1), SINEC NMS (All versions < V2.0 SP1), Totally Integrated Automation Portal (TIA Portal) V14 (All versions), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 3). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected applications that could allow an attacker to inject arbitrary JavaScript code. The code could be potentially executed later by another (possibly privileged) user.
Affected (10)
Configuration A
| Vulnerable Software | Affected Versions |
|---|---|
| All versions | |
| Before 4.1 | |
| All versions | |
| From 14.0 to 15 |
References (4)
Source: productcert@siemens.com
Source: productcert@siemens.com
PatchVendor Advisory
Source: af854a3a-2127-422b-91ae-364da2661108
Source: af854a3a-2127-422b-91ae-364da2661108
PatchVendor Advisory