CVE-2023-26293
7.8
Vector
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Exploitability: 1.8 / Impact: 5.9
Source: NVD (Secondary)
Description
A vulnerability has been identified in Totally Integrated Automation Portal (TIA Portal) V15 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions < V16 Update 7), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 6), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 1). Affected products contain a path traversal vulnerability that could allow the creation or overwrite of arbitrary files in the engineering system. If the user is tricked to open a malicious PC system configuration file, an attacker could exploit this vulnerability to achieve arbitrary code execution.
Affected (9)
Products: Siemens: Tia Portal
Configuration A
| Vulnerable Software | Affected Versions |
|---|---|
| Version 15 |
Related CWEs
CWE-20
Improper Input Validation
The product receives input or data, but it does
not validate or incorrectly validates that the input has the
properties that are required to process the data safely and
correctly.
CWE-22
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
The product uses external input to construct a pathname that is intended to identify a file or directory that is located underneath a restricted parent directory, but the product does not properly neutralize special elements within the pathname that can cause the pathname to resolve to a location that is outside of the restricted directory.
References (3)
Source: productcert@siemens.com
Source: productcert@siemens.com
PatchVendor Advisory
Source: af854a3a-2127-422b-91ae-364da2661108
PatchVendor Advisory
Timeline