← Back

CVE-2022-28376

nvd nist
Published: Apr 3, 2022Modified: Nov 21, 2024

JSON object

Loading...
8.1
Vector
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
Exploitability: 2.2 / Impact: 5.9
Source: NVD

Description

Verizon 5G Home LVSKIHP outside devices through 2022-02-15 allow anyone (knowing the device's serial number) to access a CPE admin website, e.g., at the 10.0.0.1 IP address. The password (for the verizon username) is calculated by concatenating the serial number and the model (i.e., the LVSKIHP string), running the sha256sum program, and extracting the first seven characters concatenated with the last seven characters of that SHA-256 value.

Affected (1)

1 product
Lvskihp Firmware
Configuration A
1 vulnerable · 1 platform
Vulnerable SoftwareAffected Versions
Up to 2022-02-15
Running on/withPlatform Versions
Verizon
Lvskihp
All versions

References (4)

Timeline

No history available yet.