← Back

CVE-2021-27196

nvd nist
Published: Jun 14, 2021Modified: Nov 21, 2024

JSON object

Loading...
7.5
Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Exploitability: 3.9 / Impact: 3.6
Source: NVD

Description

Improper Input Validation vulnerability in Hitachi ABB Power Grids Relion 670 Series, Relion 670/650 Series, Relion 670/650/SAM600-IO, Relion 650, REB500, RTU500 Series, FOX615 (TEGO1), MSM, GMS600, PWC600 allows an attacker with access to the IEC 61850 network with knowledge of how to reproduce the attack, as well as the IP addresses of the different IEC 61850 access points (of IEDs/products), to force the device to reboot, which renders the device inoperable for approximately 60 seconds. This vulnerability affects only products with IEC 61850 interfaces. This issue affects: Hitachi ABB Power Grids Relion 670 Series 1.1; 1.2.3 versions prior to 1.2.3.20; 2.0 versions prior to 2.0.0.13; 2.1; 2.2.2 versions prior to 2.2.2.3; 2.2.3 versions prior to 2.2.3.2. Hitachi ABB Power Grids Relion 670/650 Series 2.2.0 versions prior to 2.2.0.13. Hitachi ABB Power Grids Relion 670/650/SAM600-IO 2.2.1 versions prior to 2.2.1.6. Hitachi ABB Power Grids Relion 650 1.1; 1.2; 1.3 versions prior to 1.3.0.7. Hitachi ABB Power Grids REB500 7.3; 7.4; 7.5; 7.6; 8.2; 8.3. Hitachi ABB Power Grids RTU500 Series 7.x version 7.x and prior versions; 8.x version 8.x and prior versions; 9.x version 9.x and prior versions; 10.x version 10.x and prior versions; 11.x version 11.x and prior versions; 12.x version 12.x and prior versions. Hitachi ABB Power Grids FOX615 (TEGO1) R1D02 version R1D02 and prior versions. Hitachi ABB Power Grids MSM 2.1.0 versions prior to 2.1.0. Hitachi ABB Power Grids GMS600 1.3.0 version 1.3.0 and prior versions. Hitachi ABB Power Grids PWC600 1.0 versions prior to 1.0.1.4; 1.1 versions prior to 1.1.0.1.

Affected (29)

9 products
Relion 670 Firmware
Relion 650 Firmware
Relion Sam600 Io Firmware
Rtu500 Firmware
Reb500 Firmware
Fox615 Tego1 Firmware
Gms600 Firmware
Pwc600 Firmware
Configuration A
8 vulnerable · 1 platform
Vulnerable SoftwareAffected Versions
Hitachienergy
From 1.2.3 to 1.2.3.20
From 2.0 to 2.0.0.13
From 2.2.0 to 2.2.0.13
From 2.2.1 to 2.2.1.6
From 2.2.2 to 2.2.2.3
From 2.2.3 to 2.2.3.2
Version 1.1
Version 2.1
Running on/withPlatform Versions
Hitachienergy
Relion 670
All versions
Configuration B
6 vulnerable · 1 platform
Vulnerable SoftwareAffected Versions
Hitachienergy
From 1.3 to 1.3.0.7
From 2.2.0 to 2.2.0.13
From 2.2.1 to 2.2.1.6
Version 1.1
Version 1.2
Version 2.1
Running on/withPlatform Versions
Hitachienergy
Relion 650
All versions
Configuration C
1 vulnerable · 1 platform
Vulnerable SoftwareAffected Versions
From 2.2.1 to 2.2.1.6
Running on/withPlatform Versions
Hitachienergy
Relion Sam600 Io
All versions
Configuration D
6 vulnerable · 1 platform
Vulnerable SoftwareAffected Versions
Hitachienergy
Version 10.0
Version 11.0
Version 12.0
Version 7.0
Version 8.0
Version 9.0
Running on/withPlatform Versions
Hitachienergy
Rtu500
All versions
Configuration E
3 vulnerable · 1 platform
Vulnerable SoftwareAffected Versions
Hitachienergy
From 7.3 to 7.60.19
From 8.2 to 8.2.0.5
From 8.3 to 8.3.1.0
Running on/withPlatform Versions
Hitachienergy
Reb500
All versions
Configuration F
1 vulnerable · 1 platform
Vulnerable SoftwareAffected Versions
Before r2a16
Running on/withPlatform Versions
Hitachienergy
Fox615 Tego1
All versions
Configuration G
1 vulnerable · 1 platform
Vulnerable SoftwareAffected Versions
Before 2.1.0
Running on/withPlatform Versions
Hitachienergy
Modular Switchgear Monitoring
All versions
Configuration H
1 vulnerable · 1 platform
Vulnerable SoftwareAffected Versions
Up to 1.3.0
Running on/withPlatform Versions
Hitachienergy
Gms600
All versions
Configuration I
2 vulnerable · 1 platform
Vulnerable SoftwareAffected Versions
Hitachienergy
From 1.0 to 1.0.1.4
From 1.1 to 1.1.0.1
Running on/withPlatform Versions
Hitachienergy
Pwc600
All versions

References (14)

Timeline

No history available yet.