CVE-2021-25676
7.5
Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Exploitability: 3.9 / Impact: 3.6
Source: NVD
Description
A vulnerability has been identified in RUGGEDCOM RM1224 (V6.3), SCALANCE M-800 (V6.3), SCALANCE S615 (V6.3), SCALANCE SC-600 (All Versions >= V2.1 and < V2.1.3). Multiple failed SSH authentication attempts could trigger a temporary Denial-of-Service under certain conditions. When triggered, the device will reboot automatically.
Affected (4)
Configuration A
| Vulnerable Software | Affected Versions |
|---|---|
| Version 6.3 |
| Running on/with | Platform Versions |
|---|---|
Siemens Ruggedcom Rm1224 | All versions |
Configuration B
| Vulnerable Software | Affected Versions |
|---|---|
| Version 6.3 |
| Running on/with | Platform Versions |
|---|---|
Siemens Scalance M 800 | All versions |
Configuration C
| Vulnerable Software | Affected Versions |
|---|---|
| Version 6.3 |
| Running on/with | Platform Versions |
|---|---|
Siemens Scalance S615 | All versions |
Configuration D
| Vulnerable Software | Affected Versions |
|---|---|
| From 2.1 to 2.1.3 |
| Running on/with | Platform Versions |
|---|---|
Siemens Scalance Sc 600 | All versions |
References (4)
Source: productcert@siemens.com
Vendor Advisory
Source: productcert@siemens.com
Third Party AdvisoryUS Government Resource
Source: af854a3a-2127-422b-91ae-364da2661108
Vendor Advisory
Source: af854a3a-2127-422b-91ae-364da2661108
Third Party AdvisoryUS Government Resource
Timeline