Description
The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement encryption. An attacker with adjacent short-range access to a target product can listen to communications, including the transmission of sensitive data.
Affected (23)
Products: Medtronic: Mycarelink Monitor 24950 Firmware, Mycarelink Monitor 24952 Firmware, Carelink Monitor 2490c Firmware, Carelink 2090 Firmware, Amplia Crt D Firmware, Claria Crt D Firmware, Compia Crt D Firmware, Concerto Crt D Firmware, Concerto Ii Crt D Firmware, Consulta Crt D Firmware, Evera Icd Firmware, Maximo Ii Crt D Firmware, Maximo Ii Icd Firmware, Mirro Icd Firmware, Nayamed Nd Icd Firmware, Primo Icd Firmware, Protecta Icd Firmware, Protecta Crt D Firmware, Secura Icd Firmware, Virtuoso Icd Firmware, Virtuoso Ii Icd Firmware, Visia Af Icd Firmware, Viva Crt D Firmware
Configuration A
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Medtronic Mycarelink Monitor 24950 | All versions |
Configuration B
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Medtronic Mycarelink Monitor 24952 | All versions |
Configuration C
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Medtronic Carelink Monitor 2490c | All versions |
Configuration D
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Medtronic Carelink 2090 | All versions |
Configuration E
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Medtronic Amplia Crt D | All versions |
Configuration F
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Medtronic Claria Crt D | All versions |
Configuration G
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Medtronic Compia Crt D | All versions |
Configuration H
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Medtronic Concerto Crt D | All versions |
Configuration I
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Medtronic Concerto Ii Crt D | All versions |
Configuration J
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Medtronic Consulta Crt D | All versions |
Configuration K
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Medtronic Evera Icd | All versions |
Configuration L
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Medtronic Maximo Ii Crt D | All versions |
Configuration M
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Medtronic Maximo Ii Icd | All versions |
Configuration N
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Medtronic Mirro Icd | All versions |
Configuration O
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Medtronic Nayamed Nd Icd | All versions |
Configuration P
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Medtronic Primo Icd | All versions |
Configuration Q
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Medtronic Protecta Icd | All versions |
Configuration R
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Medtronic Protecta Crt D | All versions |
Configuration S
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Medtronic Secura Icd | All versions |
Configuration T
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Medtronic Virtuoso Icd | All versions |
Configuration U
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Medtronic Virtuoso Ii Icd | All versions |
Configuration V
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Medtronic Visia Af Icd | All versions |
Configuration W
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Medtronic Viva Crt D | All versions |
References (4)
Source: ics-cert@hq.dhs.gov
Third Party AdvisoryUS Government Resource
Source: af854a3a-2127-422b-91ae-364da2661108
Third Party AdvisoryUS Government Resource
Timeline
No history available yet.