A vulnerability has been identified in SCALANCE S602 (All versions < V4.1), SCALANCE S612 (All versions < V4.1), SCALANCE S623 (All versions < V4.1), SCALANCE S627-2M (All versions < V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface.
Affected (8)
Configuration A
| Vulnerable Software | Affected Versions |
|---|---|
| Before 5.2.4 |
| Running on/with | Platform Versions |
|---|---|
Siemens Scalance Xc 200 | All versions |
Configuration B
| Vulnerable Software | Affected Versions |
|---|---|
| Before 5.2.4 |
| Running on/with | Platform Versions |
|---|---|
Siemens Scalance Xf 200 | All versions |
Configuration C
| Vulnerable Software | Affected Versions |
|---|---|
| Before 5.2.4 |
| Running on/with | Platform Versions |
|---|---|
Siemens Scalance Xp 200 | All versions |
Configuration D
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Siemens Scalance X 200irt | All versions |
Configuration E
| Vulnerable Software | Affected Versions |
|---|---|
| Before 5.2.4 |
| Running on/with | Platform Versions |
|---|---|
Siemens Scalance Xb 200 | All versions |
Configuration F
| Vulnerable Software | Affected Versions |
|---|---|
| Before 4.1.3 |
| Running on/with | Platform Versions |
|---|---|
Siemens Scalance Xr 300wg | All versions |
Configuration G
| Vulnerable Software | Affected Versions |
|---|---|
| Before 4.1.3 |
| Running on/with | Platform Versions |
|---|---|
Siemens Scalance X 300 | All versions |
Configuration H
| Vulnerable Software | Affected Versions |
|---|---|
| Before 4.1.3 |
| Running on/with | Platform Versions |
|---|---|
Siemens Scalance Xr 300 | All versions |
Related CWEs
CWE-1021
Improper Restriction of Rendered UI Layers or Frames
The web application does not restrict or incorrectly restricts frame objects or UI layers that belong to another application or domain, which can lead to user confusion about which interface the user is interacting with.
CWE-693
Protection Mechanism Failure
The product does not use or incorrectly uses a protection mechanism that provides sufficient defense against directed attacks against the product.