Description
A vulnerability has been identified in SIMATIC Drive Controller family (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V20.8), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.4.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.8.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.8.1), SIMATIC S7-1500 Software Controller (All versions < V20.8), SIMATIC S7-1500 Software Controller (All versions >= V20.8), SIMATIC S7-PLCSIM Advanced (All versions < V3.0), SIMATIC S7-PLCSIM Advanced (All versions >= V3.0). An attacker with network access to port 102/tcp could potentially modify the user program on the PLC in a way that the running code is different from the source code which is stored on the device. An attacker must have network access to affected devices and must be able to perform changes to the user program. The vulnerability could impact the perceived integrity of the user program stored on the CPU. An engineer that tries to obtain the code of the user program running on the device, can receive different source code that is not actually running on the device.
Affected (12)
Products: Siemens: Simatic Et 200sp Open Controller Cpu 1515sp Pc Firmware, Simatic Et 200sp Open Controller Cpu 1515sp Pc2 Firmware, Simatic S7 1200 Cpu 1211c Firmware, Simatic S7 1200 Cpu 1212c Firmware, Simatic S7 1200 Cpu 1214c Firmware, Simatic S7 1200 Cpu 1215c Firmware, Simatic S7 1200 Cpu 1217c Firmware, Simatic S7 1500 Cpu 1518 Firmware, Simatic S7 1500 Cpu 1511c Firmware, Simatic S7 1500 Cpu 1512c Firmware, Simatic S7 1500 Software Controller, Simatic S7 Plcsim Advanced
Configuration A
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Siemens Simatic Et 200sp Open Controller Cpu 1515sp Pc | All versions |
Configuration B
| Vulnerable Software | Affected Versions |
|---|---|
| Before 20.8 |
| Running on/with | Platform Versions |
|---|---|
Siemens Simatic Et 200sp Open Controller Cpu 1515sp Pc2 | All versions |
Configuration C
| Vulnerable Software | Affected Versions |
|---|---|
| Before 4.4 |
| Running on/with | Platform Versions |
|---|---|
Siemens Simatic S7 1200 Cpu 1211c | All versions |
Configuration D
| Vulnerable Software | Affected Versions |
|---|---|
| Before 4.4 |
| Running on/with | Platform Versions |
|---|---|
Siemens Simatic S7 1200 Cpu 1212c | All versions |
Configuration E
| Vulnerable Software | Affected Versions |
|---|---|
| Before 4.4 |
| Running on/with | Platform Versions |
|---|---|
Siemens Simatic S7 1200 Cpu 1214c | All versions |
Configuration F
| Vulnerable Software | Affected Versions |
|---|---|
| Before 4.4 |
| Running on/with | Platform Versions |
|---|---|
Siemens Simatic S7 1200 Cpu 1215c | All versions |
Configuration G
| Vulnerable Software | Affected Versions |
|---|---|
| Before 4.4 |
| Running on/with | Platform Versions |
|---|---|
Siemens Simatic S7 1200 Cpu 1217c | All versions |
Configuration H
| Vulnerable Software | Affected Versions |
|---|---|
| Before 2.8.1 |
| Running on/with | Platform Versions |
|---|---|
Siemens Simatic S7 1500 Cpu 1518 | All versions |
Configuration I
| Vulnerable Software | Affected Versions |
|---|---|
| Before 2.8.1 |
| Running on/with | Platform Versions |
|---|---|
Siemens Simatic S7 1500 Cpu 1511c | All versions |
Configuration J
| Vulnerable Software | Affected Versions |
|---|---|
| Before 2.8.1 |
| Running on/with | Platform Versions |
|---|---|
Siemens Simatic S7 1500 Cpu 1512c | All versions |
Configuration K
| Vulnerable Software | Affected Versions |
|---|---|
| Before 20.8 | |
| Before 3.0 |
Related CWEs
CWE-345
Insufficient Verification of Data Authenticity
The product does not sufficiently verify the origin or authenticity of data, in a way that causes it to accept invalid data.
CWE-353
Missing Support for Integrity Check
The product uses a transmission protocol that does not include a mechanism for verifying the integrity of the data during transmission, such as a checksum.
References (2)
Source: productcert@siemens.com
Vendor Advisory
Source: af854a3a-2127-422b-91ae-364da2661108
Vendor Advisory