← Back

CVE-2018-7066

nvd nist
Published: Dec 7, 2018Modified: Nov 21, 2024

JSON object

Loading...
9.0
Vector
CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:C/C:H/I:H/A:H
Exploitability: 2.2 / Impact: 6.0
Source: NVD

Description

An unauthenticated remote command execution exists in Aruba ClearPass Policy Manager on linked devices. The ClearPass OnConnect feature permits administrators to link other network devices into ClearPass for the purpose of collecting enhanced information about connected endpoints. A defect in the API could allow a remote attacker to execute arbitrary commands on one of the linked devices. This vulnerability is only applicable if credentials for devices have been supplied to ClearPass under Configuration -> Network -> Devices -> CLI Settings. Resolution: Fixed in 6.7.5 and 6.6.10-hotfix.

Affected (2)

1 product
Clearpass Policy Manager
Configuration A
2 vulnerable
Vulnerable SoftwareAffected Versions
Arubanetworks
Before 6.6.10
From 6.7.0 to 6.7.5

References (2)

Source: security-alert@hpe.com
Vendor Advisory
Source: af854a3a-2127-422b-91ae-364da2661108
Vendor Advisory

Timeline

No history available yet.