← Back

CVE-2018-4842

nvd nist
Published: Jun 14, 2018Modified: Nov 21, 2024

JSON object

Loading...
4.8
Vector
CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N
Exploitability: 1.7 / Impact: 2.7
Source: NVD

Description

A vulnerability has been identified in SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.4.1), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.3). A remote, authenticated attacker with access to the configuration web server could be able to store script code on the web site, if the HRP redundancy option is set. This code could be executed in the web browser of victims visiting this web site (XSS), affecting its confidentiality, integrity and availability. User interaction is required for successful exploitation, as the user needs to visit the manipulated web site. At the stage of publishing this security advisory no public exploitation is known. The vendor has confirmed the vulnerability and provides mitigations to resolve it.

Affected (3)

3 products
Scalance X200irt Firmware
Scalance X300 Firmware
Scalance X200 Firmware
Configuration A
1 vulnerable · 1 platform
Vulnerable SoftwareAffected Versions
Before 5.4.1
Running on/withPlatform Versions
Siemens
Scalance X200 Irt
All versions
Configuration B
1 vulnerable · 1 platform
Vulnerable SoftwareAffected Versions
All versions
Running on/withPlatform Versions
Siemens
Scalance X300
All versions
Configuration C
1 vulnerable · 1 platform
Vulnerable SoftwareAffected Versions
Before 5.2.3
Running on/withPlatform Versions
Siemens
Scalance X200
All versions

References (4)

Source: productcert@siemens.com
MitigationVendor Advisory
Source: productcert@siemens.com
Source: af854a3a-2127-422b-91ae-364da2661108
MitigationVendor Advisory
Source: af854a3a-2127-422b-91ae-364da2661108

Timeline

No history available yet.