CVE-2018-16563
5.9
Vector
CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H
Exploitability: 2.2 / Impact: 3.6
Source: NVD
Description
A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions < V4.35), Firmware variant MODBUS TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions), Firmware variant Profinet IO for EN100 Ethernet module (All versions), SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.82), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.58). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the affected products. A manual restart is required to recover the EN100 module functionality of the affected devices. Successful exploitation requires an attacker with network access to send multiple packets to the affected products or modules. As a precondition the IEC 61850-MMS communication needs to be activated on the affected products or modules. No user interaction or privileges are required to exploit the vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known.
Affected (9)
Products: Siemens: Siprotec 5 With Cpu Variant Cp100, Siprotec 5 With Cpu Variant Cp200, Siprotec 5 With Cpu Variant Cp300, En100 Ethernet Module Firmware, En100 Ethernet Module With Firmware Variant Dnp3 Tcp, En100 Ethernet Module With Firmware Variant Iec104, En100 Ethernet Module With Firmware Variant Iec 61850, En100 Ethernet Module With Firmware Variant Modbus Tcp, En100 Ethernet Module With Firmware Variant Profinet Io
Configuration A
| Vulnerable Software | Affected Versions |
|---|---|
| Before 7.82 | |
| Before 7.58 | |
| Before 7.82 |
| Running on/with | Platform Versions |
|---|---|
Siemens 6md85 | All versions |
Siemens 6md86 | All versions |
Siemens 7ke85 | All versions |
Siemens 7sa82 | All versions |
Siemens 7sa86 | All versions |
Siemens 7sa87 | All versions |
Siemens 7sd82 | All versions |
Siemens 7sd86 | All versions |
Siemens 7sd87 | All versions |
Siemens 7sj82 | All versions |
Siemens 7sj85 | All versions |
Siemens 7sj86 | All versions |
Siemens 7sk82 | All versions |
Siemens 7sk85 | All versions |
Siemens 7sl82 | All versions |
Siemens 7sl86 | All versions |
Siemens 7sl87 | All versions |
Siemens 7ss85 | All versions |
Siemens 7um85 | All versions |
Siemens 7ut82 | All versions |
Siemens 7ut85 | All versions |
Siemens 7ut86 | All versions |
Siemens 7ut87 | All versions |
Siemens 7vk87 | All versions |
Configuration B
| Vulnerable Software | Affected Versions |
|---|---|
| All versions | |
| All versions | |
| All versions | |
| Version 4.35 | |
| All versions | |
| All versions |
| Running on/with | Platform Versions |
|---|---|
Siemens En100 Ethernet Module | All versions |
References (2)
Source: productcert@siemens.com
Vendor Advisory
Source: af854a3a-2127-422b-91ae-364da2661108
Vendor Advisory