CVE-2018-10599
5.3
Vector
CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N
Exploitability: 1.6 / Impact: 3.6
Source: NVD
Description
IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX100 for Rev M only), and Avalon Fetal/Maternal Monitors FM20/FM30/FM40/FM50 with software Revisions F.0, G.0 and J.3 have a vulnerability that allows an unauthenticated attacker to read memory from an attacker-chosen device address within the same subnet.
Affected (18)
Products: Philips: Intellivue Mp2 Firmware, Intellivue X2 Firmware, Intellivue Mp30 Firmware, Intellivue Mp50 Firmware, Intellivue Mp70 Firmware, Intellivue Np90 Firmware, Intellivue Mx700 Firmware, Intellivue Mx800 Firmware, Intellivue Mx400 Firmware, Intellivue Mx450 Firmware, Intellivue Mx500 Firmware, Intellivue Mx550 Firmware, Intellivue X3 Firmware, Intellivue Mx100 Firmware, Avalon Fetal/maternal Monitors Fm20 Firmware, Avalon Fetal/maternal Monitors Fm30 Firmware, Avalon Fetal/maternal Monitors Fm40 Firmware, Avalon Fetal/maternal Monitors Fm50 Firmware
Configuration A
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Philips Intellivue Mp2 | All versions |
Configuration B
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Philips Intellivue X2 | All versions |
Configuration C
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Philips Intellivue Mp30 | All versions |
Configuration D
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Philips Intellivue Mp50 | All versions |
Configuration E
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Philips Intellivue Mp70 | All versions |
Configuration F
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Philips Intellivue Np90 | All versions |
Configuration G
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Philips Intellivue Mx700 | All versions |
Configuration H
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Philips Intellivue Mx800 | All versions |
Configuration I
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Philips Intellivue Mx400 | All versions |
Configuration J
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Philips Intellivue Mx450 | All versions |
Configuration K
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Philips Intellivue Mx500 | All versions |
Configuration L
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Philips Intellivue Mx550 | All versions |
Configuration M
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Philips Intellivue X3 | All versions |
Configuration N
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Philips Intellivue Mx100 | All versions |
Configuration O
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Philips Avalon Fetal/maternal Monitors Fm20 | All versions |
Configuration P
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Philips Avalon Fetal/maternal Monitors Fm30 | All versions |
Configuration Q
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Philips Avalon Fetal/maternal Monitors Fm40 | All versions |
Configuration R
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Philips Avalon Fetal/maternal Monitors Fm50 | All versions |
References (2)
Source: ics-cert@hq.dhs.gov
Third Party AdvisoryUS Government Resource
Source: af854a3a-2127-422b-91ae-364da2661108
Third Party AdvisoryUS Government Resource
Timeline
No history available yet.